alterBiota

Case study · Moser River, NS · Cement Replacement

CarbonRun Silo Foundation

ΔC was used in the foundation pour for CarbonRun's outdoor silo, reducing embodied carbon by 21% while surpassing target strength in just 3 days.

Mix

5%ΔC-CR

Volume

14.5 m³

GWP reduction

21%

Strength target

35 MPa @ 3 days

Placing ΔC concrete
ΔC stamped in the foundation

CarbonRun outdoor limestone silo foundation, NS · 5%ΔC-CR · 21% GWP reduction

Project overview

alterBiota's ΔC admixture was used in the foundation pour for CarbonRun's outdoor silo in Nova Scotia. The mix was designed using the Cement Replacement (CR) technique, where ΔC enables a reduction in Portland limestone cement content while maintaining the required structural performance.

Volume placed
14.5 m³
Specified strength
35 MPa @ 3 days
Mix design technique
CR (Cement Replacement)
ΔC dose
5% biochar by weight of cement

Fresh-state performance

The concrete was batched at the plant and transported approximately 1.5 hours to the job site. Despite the haul time, the mix maintained workable properties and achieved the required slump and air content on site.

GHG reduction analysis

The combination of cement replacement and biochar carbon storage delivered a 21% reduction in total embodied carbon:

ΔC carbon storage (biochar)
−46 kg CO₂ e/m³
Cement reduction
−21 kg CO₂ e/m³
Total savings
−66 kg CO₂ e/m³ (21%)
Embodied carbon of ΔC mix
245 kg CO₂ e/m³

Hardened-state results

The ΔC mix achieved approximately 40 MPa at 3 days, exceeding the 35 MPa target. Strength continued to gain through 56 days. Electrical resistivity (Bulk ER) also showed consistent improvement over time, indicating good durability characteristics, reaching an average of 70 Ω·m at 56 days.

  • · Values represent the average of Batch 1 and Batch 2. Standard deviation is calculated from the two batch averages.
Dayf'c (MPa)BER (Ω·m)
340.4 ± 0.940.5 ± 2.1
545.0 ± 3.647.0 ± 4.2
747.2 ± 3.551.0 ± 5.7
1451.6 ± 1.156.5 ± 0.7
2853.0 ± 2.963.5 ± 3.5
5656.3 ± 1.170.2 ± 7.4

Key benefits

  • 35 MPa target met in 3 days with 7% less cement, demonstrating ΔC's ability to maintain early-age strength while reducing cement content and decarbonizing concrete
  • 21% reduction in embodied carbon, achieved through the combined effect of cement reduction and biochar carbon storage
  • Consistent performance across batches confirms reliable, repeatable results
  • No operational disruptions, since ΔC was added as a liquid admixture during standard batching with no equipment modifications
  • Maintained workability over long haul: the mix remained workable after a 1.5-hour transport, confirming practical job-site compatibility

Values represent the average of Batch 1 and Batch 2. Standard deviation is calculated from the two batch averages.

© alterBiota. All rights reserved. This case study, including its text, data, images, and video, may not be reproduced, distributed, or reused without prior written permission from alterBiota. Contact alterBiota for licensing inquiries.

Ready to trial ΔC at your plant?

Reach the team about samples, mix trials, or how ΔC fits your mix designs.